Parameters:
Delay Relay Module
XY-LJ02
Working Voltage:DC 6V-30V or 5V Micro USB
Control Current:10A(Max)
Quiescent Current:15mA
Working Current:50mA
Working temperature: -40~85℃
Suitable for battery:Storage Battery,Lithium battery
Trigger signal source: High level trigger (3.0V~24V), Low level trigger (0.0V~0.2V), switching control (passive switch)
Reverse protection:Yes
Physical dimension:80*38*2.1mm
Working Mode:
P1:Relay will keep ON for time OP after get trigger signal and then relay OFF;The input signal is invalid if get trigger signal again during delay time OP.
P2:Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will restart delay if get trigger signal again during delay time OP.
P3:Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will reset and stop timing if get trigger signal again during delay time OP.
P4:Relay will keep OFF for time CL after get trigger signal and then relay keep ON for time OP and then relay will OFF.
P5:Relay will keep ON for time OP after get trigger signal and then relay keep OFF for time CL and then loops the above action.Module will reset and stop timing and relay OFF if get trigger signal again during loops.The number of cycles (LOP) can be set.
P6:Relay will keep ON for time OP after power on without get trigger signal and then relay keep OFF for time CL and then loops the above action.The number of cycles (LOP) can be set.
P7:Signal hold function.Reset delay time and relay keep ON if keep get trigger signal.Relay OFF when the signal disappears.Reset delay time when get trigger signal again during timing.
Timing Range:
Continuously adjustable from 0.01 seconds to 9999 minutes.
Enter the settings interface when short press button ‘STOP’ in the OP / CL parameter modification interface(Flashing) to select timing range.
Pay attention to the position where the decimal point moves when the button is pressed.
Display ‘XXXX’.No decimal point, the timing range is 1 second ~ 9999 seconds.
Display ‘XXX.X’.The decimal point is the penultimate, timing range is 0.1 second to 999.9 seconds.
Display ‘XX.XX’.The decimal point is the third last, timing range is 0.01 second to 99.99 seconds.
Display ‘X.X.X.X’.The decimal point is fully lit, timing range is 1 minute to 9999 minutes.
For example, if you want to set the OP to 3.2 seconds, move the decimal point to the penultimate position, LCD will display ‘003.2’.
Parameter Description:
OP: Turn On time;
CL: Turn OFF time;
LOP: Number of cycles.Range is 1-9999tims.’----’ means unlimited loop.
Set Parameter:
Long press:keep press button for more than 3second.
Enter set parameter menu by long press button 'SET'.
Work mode will flash at first set the working mode.Short press the UP/DOWN button to set the working mode.
Short press the SET button to select the working mode and enter the system parameter settings.
in the system parameter setting interface, short press the ‘SET’ button to switch the system par
Related Produk
Review Produk
muh.yusufamir 5 Fitur Terbaik:menyala tapi belum di tes Sepadan dengan Harga:okelah Respon baik pengiriman cepat
budisantososantoso 5 Bagus.. program nya sesuai fungsinya... Pakingnya aman..
nyam97 5
edhar222 5